Abstract No.:
2889

 Scheduled at:
Thursday, September 29, 2011, Saal A 11:25 AM
Young Professionals


 Title:
Cold spraying of titanium using enhanced conditions and optimized nozzles

 Authors:
Kurt Binder* / Helmut-Schmidt University University of the Federal Armed Forces Hamburg, Germany
Thomas Klassen / Helmut Schmidt University, University of the Federal Armed Forces, Germany
Frank Gärtner/ Helmut Schmidt University, University of the Federal Armed Forces, Germany

 Abstract:
In the past years a number of publications reported about Titanium (Ti) coatings cold sprayed with a nominal power input between 17 to 47 KW (e.g Kinetiks 4000) reaching gas temperatures of maximum 850 °C and gas pressure of maximum 4 MPa. In a recent study at Helmut-Schmidt University (HSU), a Kinetiks 8000 prototype was used to spray Ti, employing a nominal power of about 90 KW to increase the gas temperature up to 1000°C at a pressure of 4 MPa. Under these parameters, a high tensile strength of over 480 MPa and a deposition efficiency close to 100% were achieved.

The present study focuses on further enhanced gas and particle velocities by further optimized nozzle designs. The increased particle velocities in comparison to that obtained by using commercial nozzles (D24, D51) result in better coating performance and allow deviations from ideal (90°) impact angle without significantly reducing coating strength. The influences of process conditions are evaluated and discussed on the basis of coating microstructures, nitrogen and oxygen contents, coating strength by Micro Flat Tensile (MFT) and Tubular Coating Tensile tests (TCT-test), as well as bond strength by shear tests.


<= go back